Minggu, 15 September 2013

Canon Error Code E051 E054 E055 E060 E061 E062 E063 E064 E065 E066 E067 E068 E069 E070 E071 E072

E051 The home position of the side registration cannot be detected
within a specific time.
E054 The home position of the duplexing unit feed roller cannot bedetected.
E055 The horizontal registration guide of the duplex unit exceeds its
maximum travel distance.
E060 The home position of the primary corona wire cleaner cannot be
detected within a specific time.
Relateted charging
E061 Specific potential is not be required or the limiter is activated as the
potential is controlled.
E062 The photosensitive drum temperature does not reach a specific
value due to a fault in the photosensitive drum heater, etc.
E063
The home position of the transfer corona wire cleaner cannot be
detected.
An error code is
not to be
indicated.
E064 The setting value for the output from the microcomputer
considerably deviates from the control value of the actual output.
E065 High voltage leakage from the primary corona assembly is
detected.
E066 Signals from the temperature/humidity sensor cannot be detected.
E067
Two or more faults in the primary/ pre (post)-transfer/ transfer/
separation high voltage are detected (including power output
stoppage, electric leakage from the primary corona assembly).
E068 High voltage leakage from or an open circuit in the separation
corona assembly is detected.
E069 High voltage leakage from or an open circuit in the transfer corona
assembly is detected.
E070 The home position of the transfer drum cannot be detected within a specific time.
E071 An image leading edge signal cannot be detected within a specifictime.
E072 A fault in the main motors such as the transfer drum motor, etc.
Read More..

Sabtu, 14 September 2013

E061 E100 Error Codes iR6570 Series iR5075 Series

Symptom

* E061-0001 (Potential ON)
* E061-0002 (Potential OFF)
* E100-0001
* E227-0004
Cause
* The pin is broken on the Primary Fan 2 Duct. The Laser Shutter is activated by the pin on the Primary Fan Duct Assembly. The linkage is pinched not allowing the laser shutter to be fully actuated (may also indicate E227-0004). Faulty Laser Scanner Assembly.
* Defective DC Controller PCB Assembly.

Action

1. Check the shutter operation and the pin on the Primary Fan Duct Assembly. If the
pin is broken replace the Primary Fan 2 Duct (iR6570 : FC6-3540-000 / iR5075
FL2-5834-000) or the Primary Fan Duct Assembly (iR6570 : FM2-3074-000 / iR5075
FM2-9694-000). If the Laser Scanner Assembly (iR6570 : FM2-3670-000 / iR5075
FM2-9832-000) has been replaced and error codes E100-0001/ E227-0004 are
intermittently indicated, proceed to the next step.
2. Remove the Primary Fan Duct Assembly (this assembly has a pin on it
that activates the laser shutter).
3. Remove and reinstall the Laser Scanner Assembly.
4. Install the Primary Fan Duct Assembly. This should free the linkage
allowing the laser shutter to be fully actuated.
5. Finally a DC Con clear resolved both of the intermittent issues (E100-0001/
E227-0004)

Blank Image or Dark Fogging Image (Including Blank Areas) and E061-0001 / E061-0002 Errors Occur : iR6570 Series
Approved


Symptom

* Blank copies,Dark fogging
* E061-0001 and E061-0002

Action

When the above error code/image problems are experienced, perform the following:

1. Check the potential sensor wiring harness for any damage. This is caused by the harness being trapped between the hopper assembly and the cable tie head.
2. If the cable is damaged repair or replace as necessary.
3. Reposition the head of the cable ties on the cable guide in a downward position.
4. Input "1" under Service Mode > COPIER > FUNCTION > DPC > DPC, press the OK key and switch the Main power off and on so as to forcibly execute the Potential Control.