Ads 468x60px

Pages

Tampilkan postingan dengan label techniques. Tampilkan semua postingan
Tampilkan postingan dengan label techniques. Tampilkan semua postingan

Selasa, 23 Agustus 2016

total resetter

Ni bagi bagi link dwonload

Adjustment Program untuk EPSON RX420/425/430
http://www.eaglehc.com/help/RX430.rar

Adjustment Program untuk EPSON R240/245/250
_http://www.eaglehc.com/help/R250.rar

_http://rapidshare.de/files/19836194/c67.rar.html
pass : www.apistech.net

Canon Seri MP700 tidak bisa direset tanpa penggantian waste ink pad nya

> Replace all the Ink Absorbers.
> QA4-1012-000
> QA4-1013-000
> QA4-1014-000
> QA4-1015-000
> QA4-1055-000
> Reset the counter to zero.

Prosedur reset counter :

1. Pencet tombol “menu”
2. Pencet tombol “Copy”
3. Pencet tombol “#”
4. Scroll menu sampai muncul tulisan “Test Mode” / menu ke-12
5. Pencet tombol “3? untuk menghapus Eeprom
6. Pencet tombol “0?
7. Pencet tombol “Stop”

Untuk seri mpc190/200

Prosedur reset counter :

1) Enter SERVICE MODE.—
By pressing Menu-Copy-Scan-Copy-Copy
2) Select TEST MODE.
3) Select [8] PRINTER TEST in TEST MODE.
4) Select 3. [EEPROM CLEAR].
5) Select 0. [INK COUNT].
6) Press the [OK] key.
7) Press the [Stop/Reset] key (returning to the state of 3)), and then press the [ON/OFF] key.

Silahkan dicoba….

:P

Untuk IP2000
1. Matikan printer
2. Tekan dan tahan Resume button kemudian tekan dan tahan Power button.
3. Masih menahan Power button, lepaskan Resume button
4. Tekan Resume button 2 kali kemudian lepas keduanya (Power dan resume)
5. Lampu hijau akan nyala dan berhenti berkedip
6. Ketika berhenti berkedip, tekan Resume button 4 kali
7. Tekan Power button untuk mematikan printer
8. (seharusnya) Printer akan berjalan normal kembali

tambahan reset canon
http://www.servicemanuals.ru/download/canon/ip1600st.zip

PROSEDUR RESET UNTUK CANON PIXMA iP3000, iP4000, iP5000

1. Matikan printer.
2. Tekan dan tahan Resume/Cancel button, kemudian tekan POWER button – lampu indikator akan berwarna HIJAU.
3. Lepas Resume/Cancel button, sambil tetap menahan POWER button.
4. Tekan Resume/Cancel button 2(dua) kali, kemudian lepas POWER buton
5. Lampu indikator akan berwarna HIJAU
6. Tekan Resume/Cancel button 4(empat) kali!!!
7. Matikan printer dengan menekan POWER button.
8. Idupin lagi….. eng ing eng…… jalan normal lagi tuh!!!!

Permanen reseternya masih di develop… jadi tunggu aja… kalo udah direset pake cara di atas tuh printer jangan dicabut kabel powernya, dimatikan gpp asal jangan dicabut… tar reset lagi loh….

Yang masih kesulitan untuk mendownload program adjustment printer, silahkan ke _http://www.startcopy.ru/repair/files/files.htm

Situs dalam bahasa rusia, bisa diterjemahkan pake babelfish nya altavista

Orang rusia kalo software ginian dikasih gratis, di indo. UDAH MINTA PAKE NGEMIS-NGEMIS, NAJISSSSSS……..

untuk mengetahui hasil output maksimal dari printer, coba pake program dari http://www.imatest.com

kayaknya kepanjangan masih bersambung kita minum dulu:beer:

printerku ngeblink nih. gmn btulinnya?type canon ip1200.udah cari di google tp g ad.plis bantuin ya!!!

Download ini :
iP1600ServiceToolV129.part01
iP1600ServiceToolV129.part02
iP1600ServiceToolV129.part03
iP1600ServiceToolV129.part04
iP1600ServiceToolV129.part05
iP1600ServiceToolV129.part06
iP1600ServiceToolV129.part07
iP1600ServiceToolV129.part08
iP1600ServiceToolV129.part09
iP1600ServiceToolV129.part10

kalau kurang faham cara pakainya... langsung saja hubungi aku via YM

Read More..

Kamis, 26 Mei 2016

Component Cleaning and Handling Techniques

Component Cleaning and Handling Techniques
Canon® AX,BX,EX,LX,NX,PX,VX,WX
Component Cleaning and Handling Method
Never touch the coated area of the mag roller with your fingers.
Print quality can be significantly impaired by doing so. You should
not use any type of solvent to remove residual toner from the mag
Magnetic Roller
roller surface. The best cleaning method is compressed air. OPC
case boxes are good storage areas to prevent scratches and nicks on
the mag sleeve surface.
Handle the PCR by the metal axle or use latex gloves. Apply
Anakenisis® PCR cleaner to a clean, lint free cloth, and wipe the
PCR
PCR until all residue is removed. Always wrap the PCR in a clean
cloth to prevent damage to the coated areas.
Use compressed air to remove residual toner from the surface of the
OPC. Wrap in a clean cloth, and set aside in a dark place to
minimize light exposure. Drum cases are ideal storage containers
OPC


to protect the OPC surface from light, scratches and nicks. Never
touch the coated area of the OPC with bare hands; skin oils will
cause image defects.
All urethane blades should be cleaned with a lint free cloth
Wiper/Doctor Blades
saturated with 99% IPA.
Component Cleaning and Handling Techniques
Canon® CX,SX™
Component Cleaning and Handling Method
Never touch the coated area of the mag roller with your fingers
because you can impair print quality. You should not use any type
of solvent to remove residual toner from the mag roller surface.
Magnetic Roller
Instead, sue compressed air. OPC case boxes help prevent
scratches and nicks occurring on the mag sleeve surface when used
as sleeve storage areas.
The best method for cleaning the corona assembly is to soak it in an
Ultrasonic Bath. If this is not available, you can use Scotchbrite®
Corona Assembly
and a cotton swab to gently clean the wire.
Use compressed air to remove residual toner from the surface of the
OPC. Wrap in a clean cloth, and set aside in a dark place to
minimize light exposure. Drum cases are ideal storage containers
OPC
to protect the OPC surface from light, scratches and nicks. Never
touch the coated area of the OPC with bare hands; skin oils will
cause image defects.
All urethane blades should be cleaned with a lint free cloth
Wiper/Doctor Blades
saturated with 99% IPA.