Ads 468x60px

Pages

Tampilkan postingan dengan label display. Tampilkan semua postingan
Tampilkan postingan dengan label display. Tampilkan semua postingan

Minggu, 05 Januari 2014

Xerox Phaser 6300 6350 6360 no display garbled or inverted display

If your Xerox Phaser 6300, 6350 or 6360 has a blank display, garbled characters, inverted or upside down display you most likely need to replace the control panel.

Xerox Phaser 6300 Control Panel:  Part# - 333-4419-00.    
Xerox Phaser 6350 Control Panel:  Part# - 333-4424-00.    
Xerox Phaser 6360 Control Panel:  Part# - 101E28721.    

Read More..

Sabtu, 04 Januari 2014

Xerox Phaser 7700 7750 7760 no display garbled or inverted display

If your Xerox Phaser 7700, 7750, or 7760 has a blank display, garbled characters, inverted or upside down display this video will help you repair it. Also, if you need to replace the control panel for any other reason this will help that as well.
Part numbers are:
Xerox Phaser 7700 Control Panel:  Part# - 116-0001-02.    
Xerox Phaser 7750 Control Panel:  Part# - 333-4409-00.    
Xerox Phaser 7760 Control Panel:  Part# - 101K57542.    

Read More..

Senin, 23 September 2013

Samsung SyncMaster 540N with power but no display problem


The complaint for this Samsung SyncMaster 540n monitor was its take a while before the display comes, some times half an hour some times 15 minutes. I have repaired several of these in our shop and they all have the same exact issue with the power supply. If you have a Samsung SyncMaster 540n with the same problem this should help get you back running.


First you need to remove the power cable, signal cable and the stand. To remove the stand you will need to remove the 3 thumbscrews, they are circled in red.


Remove the cover, to remove the cover you will need to use the small flat blade screwdriver. Across the side there are several release tabs, if you insert the screwdriver into the slot, the case will release.


After the plastic cover is removed. You will need to unplug the control panel and the 2 backlight connector, circled in red. The last cable to release is the panel signal cable, circled in blue. After unplug the 3 connector slightly lift up the metal case and unplug the panel signal cable.


To remove the board you need to unscrew the 3 screws circled in red and unplug the signal cable, circled in blue.


Capacitor that need to be replaced are circled in yellow. As you can see in the picture above the caps had very noticeable bulging tops. This caps is the source of the problem, in other cases there 2 or 3 bulging caps so you have to replace them all. Be sure to reinstall the caps with the polarity stripe going the same direction as the old ones come out.


After the replacement of parts. Apply power and you should have a fully functional monitor again.

Read More..